| Physical size: |
H: 58” / 1485 mm, W: 58” / 1465 mm, D: 62” / 1585 mm; Weight: 1.3 t
|
| Power requirement: |
230 VAC, 50/60 Hz, 1.5 KW or 115 VAC, 50/60 Hz, 1.5 KW (350 W when idle!) |
| Compressed air or nitrogen: |
60 L/min @ 1.8 bar |
| Accuracy: |
± 0.4 mil / 9 µm -absolute
± 0.2 mil / 4 µm -repeatability |
| Technology: |
XENON-DMD Raster Image Projection Technology |
| Environment: |
Dependent on resist/emultion sensitivity - yellow, red or green safe light conditions for loading panels or other media. |
| Recommended temperature: |
21°C |
| Recommended humidity: |
50% |
| Media: |
Resist coated panels or silver halide film or plates up to 0.25” thick. |
| User dialogue: |
Simple instructions for programming and operation by keyboard or remote control |
| Communications: |
Local area network, CD-ROM, Floppy Disk |
| Protocol emulations: |
Gerber, RS 274-X, HP-GL, Fire 9000
PostScript, TIFF, PCX, others on request |
| User interface: |
Netlink xDI queue manager (Win 9x, 2000 and XP compatible) – runs from anywhere on your host network |
| Panel registration: |
Registration pins or optical registration system |